Why choose colocation? Since the benefits are numerous.

The many benefits of Colocation

Listed here is a way that is simple explain what colocation is: your equipment is hosted by a colocation service provider in a highly secure facility and monitored by a team of technical experts. Companies specializing in colocation provide security for the infrastructure and building, along with the availability of electricity and cooling, fire protection and redundancy systems. Specialized gear, like servers, requires special attention, and that is precisely what colocation companies offer.

 

Dependable connectivity

Accessibility to the community at all times is essential. One of the most things that are important colocation providers make certain of is the fact that your equipment is connected to the planet at all times, without interruption. They conduct frequent interviews to ensure that everything is working well, and their structure guarantees no downtime.

Redundancy

One of the key elements to ensure network availability at all times is redundancy. Colocation and data centers offer N + 1 redundancy. This means that the number of devices (letter) has at least one amount of redundancy. For instance, generators are in place in the big event of a power failure.

Green energy

Information facilities eat a lot of power, so it made sense to build them in places where green energy is affordable. For example, The Email Shop UK colocation facilities in Montreal are powered by hydroelectricity. This energy is both affordable and renewable. In the event your business encourages the usage of renewable power sources, it creates sense that is perfect it really wants to install its energy-consuming gear in a spot where green energy is the norm.

Fire protection

Needless to say, your installations that are current a fire protection system. Of course. However, special fire protection is required for servers. Since they consume a lot of electricity, they are easily damaged by water.

Colocation centers employ active and measures that are passive fire protection. Passive measures include the presence of very smoke that is sensitive which detect the smoldering fire into the electrical elements before the flames begin. Also, firewalls divide the area to stop the fire from spreading. Active measures range from the existence of a sprinkler system or other systems to extinguish the fire.

Cooling systems

Regarding room heat, servers and individuals aren’t the best office colleagues. Servers and other system equipment require a cold, managed environment.

Colocation providers monitor the heat at different particular locations and make certain that there is certainly air that is sufficient to keep the equipment in top condition. Of course, places like Canada are ideal for setting up data and colocation centers, since the climate that is cold a lot of this air-con work.

Colocation service providers also monitor humidity levels. Information centers which are found in the wetlands will keep the temperature below the dew point to prevent condensation. In places with low humidity, a humidifier system will be installed to avoid any spark caused by static electricity cheap ssl certificate uk.

Multilayer security

Servers host the most sensitive and critical information of an enterprise, and their protection has to take this under consideration.

Colocation service providers offer a multi-layered approach to security. They can set up cameras and closed-circuit television (CCTV) systems, perform access control by biometric identification and offer cages to secure each tenant’s gear. Besides, they will have staff on site to cut back any probability of breaches of site safety.

Benefits of having host colocation solutions within the cheap email hosting

Energy supply guarantee 10 MVA

Electromagnetic compatibility: Transformation station Medium voltage voltage that is/ low station on location (5 transformers of 2,500 kVA, N + 1 redundancy), sufficient distance from accommodation and telecoms spaces (electrosmog)

High low voltage current distribution Double electrical distribution network with transparent switching <10 Ms via load transfer modules (STS). Each rack is connected via the energy rails to 2 separate electrical panels (N + N redundancy).

Uninterruptible power supply each branch of electrical circulation is protected by dynamic inverters with kinetic energy accumulation (5 No Break of 2,500 kVA, N + 1 redundancy). All cooling systems are supplied without disruption.

Emergency power Each electrical distribution branch is protected by a diesel generator (5 groups of 2,500 kVA directly attached to dynamic inverters, N + 1 redundancy), each provided with redundant gas (2 main tanks + 5 day-to-day tanks for an overall total of 160,000 litters saved on-site, matching to 80 hours of autonomy at full load, with additional supply program).

Power available – accommodation rooms: between 1,500 W / m2 and 3,600 W / m2 depending on the room plumped for (between 4,000 W and 12,000 W per rack on average, this power may be extended depending on the fitting out of accommodation space).

Manufacturing 4 2,500 kW turbo teams (N + N redundancy), 2 free cooling exchangers using cold air that is outside

Cooling systems

Circulation Double chilled water distribution system (N + N redundancy)

Air conditioning units 50 kW per device for liquid cooling (N + N redundancy), 55 kW per unit for air cooling outside the accommodation rooms (N + 1 redundancy)

Power supply all cold production and circulation systems, along with air conditioning units, are supplied without disruption.

Physical security: access, fire, and water

Perimeter fenced plot (min-height 3.5 m), patrols

Building secure best email hosting, single-pass airlock, biometric access control system with a brief history

Audio/video monitoring interior and outdoor surveillance with history

Intrusion detection zone coverage, monitoring of access doorways to your containment that is various, detection inside and outside the building

Containment 5 levels

Protection staff 24/7 on-site presence

Fire detection total fire detection through the building

Fire protection – compartmentalization of accommodation rooms, telecom rooms and rooms that are technical fire walls and fire doors

Automated extinguishing system by water mist for accommodation spaces

Particular fire extinguishers in every available rooms and technical neighborhood

Leak detection on all cooling networks server colocation

Flood protection interior and outdoor drainage and drainage systems, no pipelines over the accommodation spaces

Connectivity

Interconnection for operators 4 interconnection spaces on the plot

Introductions (pipe batteries) 4 introductions that are separate the building

Telecoms spaces 2 separate rooms into the building, each offered by 2 introductions and 2 interior that is separate

Datacentre administration

An operational organization based on ISO20000 / ITIL approaches

Supervision 24/7 on infrastructure and all sorts of installments

Detailed procedures according to the operating manual

Conclusion

In the event your company has servers or network and storage equipment, it can be tempting to host it on your premises. However, offices are the first and requirement that is foremost to meet up the requirements of staff uk colocation. Servers and other complex equipment require other more specialized and technical requirements. This is why colocation services are a choice that is wise.server colocation